Evaluasi Daya Dukung Aksial Pondasi Bored Pile Berdasarkan Data SPT dan Pembebanan Gempa pada Gedung Landmark Mandiri Kendari
Abstract
This study evaluates the bearing capacity of bored pile foundations at the Landmark Mandiri Kendari project using the Meyerhof method and Standard Penetration Test (SPT) data. Three pile depths (34, 36, and 40 m) were compared for 0.80 m diameter piles. Structural loading was analyzed using ETABS with reference to SNI 1727:2020 and SNI 1726:2019. The seismic weight and dynamic base shear were 78,063.98 kN and 3,297.42 kN, respectively; the maximum factored axial force at grid B3 was 6,250 kN. Calculated allowable single-pile capacities were 3,368.15 kN (34 m), 3,812.87 kN (36 m), and approximately 4,503.46 kN (40 m), based on the tabulated ultimate capacity and safety factor of 2.0. Increasing depth from 34 to 36 m raised allowable capacity by 13.20%. The existing 34 m depth may be adequate when pile-group capacity and load distribution are verified, while the 36 m option provides additional axial resistance. Confirmation of group efficiency, settlement, and seismic load combinations remains necessary before final design decisions.
Downloads
Copyright (c) 2026 Muhammad Muhsar, Muhammad Fathur Aditya, Ayu Saraswati, Christi Tricahyaning Tumanan