Evaluasi Daya Dukung Aksial Pondasi Bored Pile Berdasarkan Data SPT dan Pembebanan Gempa pada Gedung Landmark Mandiri Kendari

  • Muhammad Muhsar Universitas Sulawesi Tenggara
  • Muhammad Fathur Aditya Universitas Sulawesi Tenggara
  • Ayu Saraswati Universitas Sulawesi Tenggara
  • Christi Tricahyaning Tumanan Universitas Sulawesi Tenggara
Keywords: bored pile, Meyerhof, SPT, bearing capacity, seismic loading.

Abstract

This study evaluates the bearing capacity of bored pile foundations at the Landmark Mandiri Kendari project using the Meyerhof method and Standard Penetration Test (SPT) data. Three pile depths (34, 36, and 40 m) were compared for 0.80 m diameter piles. Structural loading was analyzed using ETABS with reference to SNI 1727:2020 and SNI 1726:2019. The seismic weight and dynamic base shear were 78,063.98 kN and 3,297.42 kN, respectively; the maximum factored axial force at grid B3 was 6,250 kN. Calculated allowable single-pile capacities were 3,368.15 kN (34 m), 3,812.87 kN (36 m), and approximately 4,503.46 kN (40 m), based on the tabulated ultimate capacity and safety factor of 2.0. Increasing depth from 34 to 36 m raised allowable capacity by 13.20%. The existing 34 m depth may be adequate when pile-group capacity and load distribution are verified, while the 36 m option provides additional axial resistance. Confirmation of group efficiency, settlement, and seismic load combinations remains necessary before final design decisions.

Downloads

Download data is not yet available.
Published
2026-11-23
How to Cite
Muhsar, M., Aditya, M., Saraswati, A., & Tumanan, C. (2026). Evaluasi Daya Dukung Aksial Pondasi Bored Pile Berdasarkan Data SPT dan Pembebanan Gempa pada Gedung Landmark Mandiri Kendari. Sultra Civil Engineering Journal (SCiEJ), 7(2), 321-328. https://doi.org/10.54297/sciej.v7i2.1623

Most read articles by the same author(s)